1 |
|
calibration directive HV modulator lower voltage index |
index of the lower voltage of the HV modulator window (ATBD Table 3.5); each voltage
window correlates directly to a proton bulk flow speed |
1 |
|
calibration directive exponent |
calibration directive exponent (0 = current off, 1 = -14, 2 = -13, 3 = -12, 4 = -11,
5 = -10, 6 = -9) |
1 |
|
collector A mux range |
collector A multiplexor range setting |
1 |
|
collector A HV modulation state |
collector A HV modulation state (0 = on, 1 = off) |
1 |
|
calibration directive chain select |
calibration directive chain select (0 = apply to all, 1 = only collector chain A,
2 = only chain B, 3 = only chain C) |
1 |
|
time |
date and time for each observation |
1 |
|
calibration directive multiplier |
calibration directive multiplier (0 = 3x, 1 = 10x) |
1 |
|
calibration directive modulation |
calibration directive modulation (0 = off, 1 = on, i.e., in calibration mode) |
1 |
|
collector B HV modulation state |
collector B HV modulation state (0 = on, 1 = off) |
1 |
|
collector A analog to digital value |
collector A analog to digital value |
1 |
|
collector B analog to digital value |
collector B analog to digital value |
1 |
|
collector B mux range |
collector B multiplexor range setting |
1 |
|
collector C mux range |
collector C multiplexor range setting |
1 |
|
collector C HV modulation state |
collector C HV modulation state (0 = on, 1 = off) |
1 |
|
backfilled_data_flag |
One or more measurements were backfilled from the spacecraft recorder and therefore
were not available to forecasters in real-time |
1 |
|
collector C analog to digital value |
collector C analog to digital value |
1 |
|
packet_time_older_than_threshold_flag |
One or more measurements were extracted from a packet whose timestamp was older than
the threshold at the point of processing |
1 |
|
packet_time_in_future_flag |
One or more measurements were extracted from a packet whose timestamp was in the future
at the point of processing |
1 |
|
loss_of_proton_peak_flag |
Loss of proton peak |
1 |
|
fill_flag |
Fill |
1 |
|
calibration_mode_flag |
Instrument in calibration mode |
1 |
|
AOCS_non_science_mode_maneuver_or_safehold_flag |
AOCS non-science mode (spacecraft maneuver/safehold) |
1 |
|
reduced_proton_data_quality_flag |
Reduced proton data quality; peak identified but resulting science data subject to
high uncertainties |
1 |
|
loss_of_alpha_particle_peak_flag |
Loss of alpha particle peak |
1 |
|
reduced_alpha_particle_data_quality_flag |
Reduced alpha particle data quality; peak identified but resulting science data subject
to high uncertainties |