70504B 32 1 240 260 507.50 507.75FUR 139 3 ICR1 R 2.9@-3 -46. 165 1.4@-3 6. 2 COL-PYX-PLAG PHYRIC BASALT,ALT MOD* 3 70504B 32 1 490 510 507.50 508.00FUR 142 3 ICR1 R 5.1@-3 -45. 88 3.2@-3 5. 2 COL-PYX-PLAG PHYRIC BASALT,ALT MOD* 3 70504B 32 1 960 980 507.50 508.47FUR 149 3 ICR1 R 6.4@-3 -35. 86 3.3@-3 6. 2 COL-PYX-PLAG PHYRIC BASALT,ALT MOD* 3 70504B 32 2 180 507.50 509.18PECH 160 4 ISR1 R 2 X 410 0.680 196 3 COL-PLAG PHYRIC BASALT,ALT MOD* 4 70504B 32 2 190 210 507.50 509.20FUR 160 3 ICR1 R 8.4@-3 -14. 141 2.4@-3 10. 2 COL-PYX-PLAG PHYRIC BASALT,ALT MOD* 3 70504B 32 2 550 570 507.50 509.56FUR 165 3 ICR1 R 8.6@-3 -29. 140 2.5@-3 11. 2 COL-PYX-PLAG PHYRIC BASALT,ALT MOD* 3 70504B 33 1 730 750 516.50 517.24FUR 191 3 ICR1 R 14.2@-3 4. 89 2.2@-3 19. 2 COL-PLAG PHRYIC BASALT,ALT MOD* 3 70504B 33 1 940 516.50 517.44PECH 194 4 ISR1 R 1267.@-6 2 X 380 0.756 108 3 COL-PLAG PHYRIC BASALT,ALT MOD* 4 70504B 33 2 720 740 516.50 518.73FUR 210 6 ICR1 R 2 XH 350 3 XC 320 4 XH 485 5 COL-PLAG PHYRIC BASALT,ALT MOD* 6 70504B 33 212601280 516.50 519.27FUR 216 3 ICR1 R 18.2@-3 15. 111 2.2@-3 26. 2 COL-PLAG PHRYIC BASALT,ALT MOD* 3 70504B 34 1 630 525.50 526.13PECH 226 4 ISR1 R 649.@-6 2 X 420 0.570 242 3 COL-PLAG PHYRIC BASALT,ALT MOD* 4 70504B 34 2 180 525.50 527.18PECH 240 4 ISR1 R 328.@-6 2 X 400 0.215 340 3 CPLAG-OL MOD PHYRIC BASALT,ALT MOD* 4 70504B 34 2 590 610 525.50 527.60FUR 240 5 ISR1 R 2 XH 525 3 XC 440 4 CPLAG-OL MOD PHYRIC BASALT,ALT MOD* 5 70504B 34 211801200 525.50 528.19FUR 253 3 ICR1 R 14.7@-3 7. 152 1.5@-3 29. 2 CPLAG-OL MOD PHYRIC BASALT,ALT MOD* 3 70504B 35 1 440 460 534.50 534.95FUR 264 3 ICR1 R 5.5@-3 -31. 90 1.4@-3 12. 2 CPLAG-OL MOD PHYRIC BASALT,ALT MOD* 3 70504B 35 1 960 534.50 535.46PECH 272 4 ISR1 R 459.@-6 2 X 390 0.443 265 3 CPLAG-OL MOD PHYRIC BASALT,ALT MOD* 4 70504B 35 110901120 534.50 535.60FUR 274 4 ICR1 R 3.5@-3 -36. 374 0.3@-3 34. 2 CPLAG-CPX-OL SPARSELY TO MOD PHYRIC BASALT,ALT 3 CMOD* 4 70504B 35 111601180 534.50 535.67FUR 275 4 ICR1 R 5.1@-3 -27. 178 1.1@-3 14. 2 CPLAG-CPX-OL SPARSELY TO MOD PHYRIC BASALT,ALT 3 CMOD* 4 70504B 35 2 420 440 534.50 536.43FUR 288 4 ICR1 R 2.8@-3 -28. 95 1.4@-3 6. 2 CPLAG-CPX-OL SPARSELY TO MOD PHYRIC BASALT,ALT 3 CMOD* 4 70504B 35 2 530 560 534.50 536.55FUR 287 4 ICR1 R 4.4@-3 -36. 110 1.1@-3 13. 2 CPLAG-CPX-OL SPARSELY TO MOD PHYRIC BASALT,ALT 3 CMOD* 4 70504B 36 1 780 800 543.50 544.29FUR 4 ICR1 R 1.8@-3 -30. 54 2.6@-3 2.1 2 CPLAG-CPX-OL SPARSELY TO MOD PHYRIC BASALT,ALT 3 CMOD,PCE NUMBER=299B* 4 70504B 36 1 880 543.50 544.38PECH 5 ISR1 R 1241.@-6 2 X 315 1.253 97 3 CPLAG-CPX-OL SPARSELY TO MOD PHYRIC BASALT,ALT 4 CMOD,PCE NUMBER=300A* 5 70504B 36 2 680 700 543.50 545.69FUR 309 4 ICR1 R 0.8@-3 -26. 99 2.4@-3 1.0 2 CPLAG-CPX-OL SPARSELY TO MOD PHYRIC BASALT,ALT 3 CMOD* 4 70504B 36 2 850 870 543.50 545.86FUR 311 5 ICR1 R 2 XC 190 3 XH 295 80 4 CPLAG SPARSELY PHYRIC BASALT,ALT MOD* 5 70504B 36 3 160 180 543.50 546.67FUR 318 5 ICR1 R 2 XC 370 3 XH 385 4 CPLAG-CPX MOD PHYRIC TO PHYRIC BASALT,ALT MOD* 5 70504B 36 310101030 543.50 547.52FUR 325 4 ICR1 R 2.7@-3 -26. 60 2.5@-3 3.3 2 CPLAG-CPX-OL SPARSELY TO MOD PHYRIC BASALT,ALT 3 CMOD* 4 70504B 36 31100 543.50 547.60PECH 325 5 ISR1 R 1189.@-6 2 X 290 1.190 70 3 CPLAG-CPX-OL SPARSELY TO MOD PHYRIC BASALT,ALT 4 CMOD* 5 70504B 37 111501170 552.50 553.66FUR 357 4 ICR1 R 9.7@-3 -31. 101 2.0@-3 14. 2 CPLAG-OL-CPX SPARSELY TO MOD PHYRIC BASALT,ALT 3 CMOD* 4 70504B 37 3 180 552.50 555.68PECH 391 5 ISR1 R 1100.@-6 2 X 410 0.729 125 3 CPLAG-OL-CPX SPARSELY TO MOD PHYRIC BASALT,ALT 4 CMOD* 5 70504B 37 3 510 540 552.50 556.03FUR 397 4 ICR1 R 3.0@-3 -12. 90 2.7@-3 3.4 2 CPLAG-OL-CPX SPARSELY TO MOD PHYRIC BASALT,ALT 3 CMOD* 4 70504B 38 1 840 860 561.50 562.35FUR 419 5 ICR1 R 10.4@-3 6. 128 2 XH 485 3 XC 455 4 CPLAG-OL-CPX MOD PHYRIC BASALT,ALT MOD* 5 70504B 38 211001130 561.50 564.12FUR 450 3 ICR1 R 8.9@-3 10. 92 2 CPLAG-OL-CPX MOD PHYRIC BASALT,ALT MOD* 3 70504B 38 212901310 561.50 564.30FUR 452 3 ICR1 R 11.0@-3 15. 94 2.9@-3 11. 2 CPLAG-OL-CPX MOD PHYRIC BASALT,ALT MOD* 3 70504B 39 1 480 500 570.50 570.99FUR 462 3 ICR1 R 7.6@-3 -11. 89 2.1@-3 11. 2 CPLAG-CPX MOD PHYRIC BASALT,ALT MOD,STA INC?* 3 70504B 39 110401070 570.50 571.56FUR 470 3 ICR1 R 2.5@-3 7. 66 3.4@-3 2. 2 CPLAG-OL SPARSELY PHYRIC BASALT,ALT MOD* 3 70504B 39 211801200 570.50 573.19FUR 494 3 ICR1 R 4.0@-3 6. 85 2.1@-3 6. 2 CPLAG-OL-CPX MOD PHYRIC BASALT,ALT MOD* 3 70504B 39 213501380 570.50 573.37FUR 496 3 ICR1 R 3.6@-3 6. 88 1.9@-3 6. 2 CPLAG-OL-CPX MOD PHYRIC BASALT,ALT MOD,STA INC?* 3 70504B 40 112401260 579.50 580.75FUR 520 3 ICR1 R 1.8@-3 5. 39 2.3@-3 2.4 2 CPLAG-OL-CPX MOD PHYRIC BASALT,ALT SLIGHT* 3 70504B 40 3 560 580 579.50 583.07FUR 548 5 ICR1 R 4.1@-3 5. 209 1.9@-3 6. 2 XC 185 3 XH 250 4 CPLAG-OL-CPX MOD PHYRIC BASALT,ALT SLIGHT* 5 70504B 41 1 380 584.00 584.38PECH 582 4 ISR1 R 987.@-6 2 X 280 0.900 60 3 CPLAG-OL-CPX MOD PHYRIC BASALT,ALT SLIGHTLY* 4 70504B 41 111301160 584.00 585.15FUR 593 5 ICR1 R 2 XH 260 3 XC 190 4 CPLAG-OL-CPX MOD PHYRIC BASALT,ALT MOD* 5 70504B 41 111801200 584.00 585.19FUR 594 3 ICR1 R 3.7@-3 3. 139 2.0@-3 6. 2 CPLAG-OL-CPX MOD PHYRIC BASALT,ALT SLIGHT* 3 70504B 41 3 30 50 584.00 587.04FUR 614 3 ICR1 R 4.2@-3 7. 92 2.0@-3 6. 2 CPLAG-OL-CPX MOD PHYRIC BASALT,ALT SLIGHT* 3 70504B 41 311201140 584.00 588.13FUR 625 3 ICR1 R 3.3@-3 6. 84 2.4@-3 4.3 2 CPLAG-OL-CPX MOD PHYRIC BASALT,ALT SLIGHT* 3 70504B 42 1 320 593.00 593.32PECH 646 4 ISR1 R 1948.@-6 2 X 415 1.317 68 3 CPLAG-CPX SPARSELY TO MOD PHYRIC BASALT,ALT MOD* 4 70504B 42 1 970 990 593.00 593.98FUR 653 3 ICR1 R 3.1@-3 -65. 110 4.0@-3 2.4 2 CPLAG-CPX SPARSELY TO MOD PHYRIC BASALT,ALT MOD* 3 70504B 42 2 480 510 593.00 594.99FUR 666 3 ICR1 R 2.9@-3 -62. 129 3.2@-3 2.8 2 CPLAG-CPX SPARSELY TO MOD PHYRIC BASALT,ALT MOD* 3 70504B 42 2 800 840 593.00 595.32FUR 668 6 ICR1 R 2 XH 420 3 XC 480 4 XH 475 5 CPLAG-CPX SPARSELY TO MOD PHYRIC BASALT,ALT MOD* 6 70504B 43 1 660 690 602.50 603.17FUR 679 3 ICR1 R 0.1@-3 -51. 137 2.7@-3 0.1 2 CPLAG-CPX SPARSELY TO MOD PHYRIC BASALT,ALT MOD* 3 70504B 43 2 140 170 602.50 604.16FUR 695 3 ICR1 R 0.9@-3 -79. 89 2.8@-3 1.0 2 CPLAG-CPX SPARSELY TO MOD PHYRIC BASALT,ALT MOD* 3 70504B 44 1 220 250 611.00 611.24FUR 701 3 ICR1 R 7.6@-3 -44. 98 2.3@-3 10. 2 CPLAG-CPX SPARSELY TO MOD PHYRIC BASALT,ALT MOD* 3 70504B 44 2 650 611.00 613.15PECH 725 4 ISR1 R 1345.@-6 2 X 405 1.100 80 3 CPLAG-CPX-OL MOD PHYRIC BASALT,ALT MOD* 4 70504B 44 2 880 910 611.00 613.40FUR 728 3 ICR1 R 10.5@-3 -49. 88 2.3@-3 14. 2 CPLAG-CPX-OL MOD PHYRIC BASALT,ALT MOD* 3 70504B 45 1 100 120 620.00 620.11FUR 732 5 ICR1 R 2 XC 270 3 XH 420 4 CGLOMEROPHYRIC BASALT,ALT MOD* 5 70504B 45 111801210 620.00 621.20FUR 747 3 ICR1 R 2.2@-3 -28. 82 4.0@-3 1.7 2 CPLAG-OL-CPX MOD PHYRIC BASALT,ALT MOD* 3 70504B 46 1 700 629.00 629.70PECH 774 4 ISR1 R 1196.@-6 2 X 435 1.006 127 3 CPLAG-OL-CPX MOD PHYRIC BASALT,ALT MOD* 4 70504B 46 1 800 850 629.00 629.83FUR 775 3 ICR1 R 12.2@-3 -47. 17 2.2@-3 105. 2 CPLAG-OL-CPX MOD PHYRIC BASALT,ALT SLIGHT* 3 70504B 46 31060 629.00 633.06PECH 803 4 ISR1 R 632.@-6 2 X 430 0.578 180 3 CPLAG-OL-CPX MOD PHYRIC BASALT,ALT SLIGHTLY* 4 70504B 47 2 200 638.00 639.70PECH 824 4 ISR1 R 1177.@-6 2 X 385 1.072 120 3 CPLAG-OL-CPX MOD PHYRIC BASALT,ALT MOD* 4 70504B 47 2 200 230 638.00 639.72FUR 824 3 ICR1 R 7.6@-3 1. 68 3.4@-3 7. 2 CPLAG-OL-CPX MOD PHYRIC BASALT,ALT SLIGHT* 3 70504B 47 2 390 420 638.00 639.91FUR 826 3 ICR1 R 3.3@-3 9. 52 3.1@-3 3.2 2 CPLAG-CPX-OL PHYRIC BASALT,ALT MOD* 3 70504B 47 3 360 638.00 641.36PECH 840 4 ISR1 R 1715.@-6 2 X 425 1.237 80 3 CPLAG-OL-CPX PHYRIC BASALT,ALT SLIGHTLY* 4 70504B 48 1 460 490 647.00 647.48FUR 864 3 ICR1 R 9.4@-3 2. 84 3.3@-3 9. 2 CPLAG-CPX-OL SPARSELY PHYRIC BASALT,ALT MOD* 3 70504B 48 2 90 110 647.00 648.60FUR 876 6 ICR1 R 2 XC 210 3 XH 420 4 CPLAG-CPX-OL SPARSELY TO MOD PHYRIC BASALT,ALT 5 C MOD* 6 70504B 48 2 750 780 647.00 649.27FUR 884 4 ICR1 R 12.5@-3 -2. 88 2.9@-3 13. 2 CPLAG-CPX-OL SPARSELY TO MOD PHYRIC BASALT,ALT 3 CMOD* 4 70504B 48 3 820 850 647.00 650.84FUR 902 3 ICR1 R 6.6@-3 -26. 92 2.9@-3 7. 2 CPLAG PHYRIC BASALT,ALT SLIGHT* 3 70504B 48 31420 647.00 651.42PECH 909 5 ISR1 R 1244.@-6 2 X 420 0.971 148 3 CAPHYRIC TO PLAG-OL-CPX MOD PHYRIC BASALT,ALT 4 CSLIGHTLY* 5 70504B 49 114101430 656.00 657.42FUR 934 3 ICR1 R 13.5@-3 -34. 133 2.0@-3 20. 2 CPLAG-OL MOD PHYRIC BASALT,ALT MOD* 3 70504B 49 2 180 200 656.00 657.69FUR 937 3 ICR1 R 6.4@-3 -15. 148 1.3@-3 15. 2 CPLAG-OL MOD PHYRIC BASALT,ALT SLIGHT* 3 70504B 49 2 850 656.00 658.35PECH 946 4 ISR1 R 1604.@-6 2 X 440 1.160 107 3 CPLAG-OL PHYRIC BASALT,ALT MOD* 4 70504B 49 3 20 50 656.00 659.03FUR 952 3 ICR1 R 9.3@-3 -31. 102 3.0@-3 9. 2 CPLAG-OL MOD PHYRIC BASALT,ALT MOD* 3 70504B 50 1 280 300 665.00 665.29FUR 962 3 ICR1 R 27.7@-3 -15. 145 2.3@-3 37. 2 CPLAG-OL MOD PHYRIC BASALT,ALT MOD* 3 70504B 51 1 150 669.50 669.65PECH 972 5 ISR1 R 1091.@-6 2 X 310 1.062 62 3 CPLAG-OL SPARSELY TO MOD PHYRIC BASALT,ALT 4 CSLIGHTLY* 5 70504B 51 1 690 720 669.50 670.21FUR 980 3 ICR1 R 2.6@-3 -17. 109 2.5@-3 3.1 2 CPLAG-OL SPARSELY TO MOD PHYRIC BASALT,ALT SLIGHT*3 70504B 52 2 300 320 678.50 680.31FUR 6 ICR1 R 2 XH 325 3 XC 300 4 CPLAG-OL SPARSELY TO MOD PHYRIC BASALT,ALT MOD, 5 CPCE NUMBER=1011* 6 70504B 52 212801310 678.50 681.30FUR 4 ICR1 R 2.7@-3 -11. 77 2.8@-3 2.9 2 CPLAG-OL SPARSELY TO MOD PHYRIC BASALT,ALT MOD, 3 CPCE NUMBER=1021* 4 70504B 52 4 930 960 678.50 683.95FUR 4 ICR1 R 3.4@-3 -8. 75 2.5@-3 4.1 2 CPLAG-OL SPARSELY TO MOD PHYRIC BASALT,ALT MOD, 3 CPCE NUMBER=1049* 4 70504B 53 1 400 687.50 687.90PECH 5 ISR1 R 1952.@-6 2 X 460 1.415 78 3 CPLAG-OL SPARSELY TO MOD PHYRIC BASALT,ALT MOD,PCE4 CNUMBER=1057* 5 70504B 54 1 640 660 692.00 692.65FUR 3 ICR1 R 4.7@-3 -36. 90 3.4@-3 1.4 2 CAPHYRIC BASALT,ALT MOD,PCE NUMBER=1065* 3 70504B 55 2 240 260 696.50 698.25FUR 4 ICR1 R 0.5@-3 -34. 79 4.1@-3 0.4 2 CAPHYRIC TO SPARSELY GLOMEROPHYRIC BASALT,PCE 3 CNUMBER=1097* 4 70504B 56 2 660 705.50 707.66PECH 5 ISR1 R 1605.@-6 2 X 420 1.216 90 3 CAPHYRIC TO SPARSELY GLOMEROPHYRIC BASALT,ALT MOD,4 CPCE NUMBER=1120* 5 70504B 56 2 660 680 705.50 707.67FUR 4 ICR1 R 3.4@-3 -31. 94 3.4@-3 3.1 2 CAPHYRIC TO SPARSELY GLOMEROPHYRIC BASALT,PCE 3 CNUMBER=1120* 4 70504B 57 1 380 410 714.50 714.90FUR 3 ICR1 R 4.1@-3 -19. 76 4.1@-3 3.0 2 CAPHYRIC BASALT,ALT MOD,PCE NUMBER=1130* 3 70504B 57 214001420 714.50 717.41FUR 5 ICR1 R 2 XH 330 3 XC 215 4 COL SPARSELY PHYRIC BASALT,ALT MOD* 5 70504B 57 31050 714.50 718.55PECH 5 ISR1 R 1631.@-6 2 X 375 1.318 73 3 COL SPARSELY TO MOD PHYRIC BASALT,ALT SLIGHTLY,PCE4 CNUMBER=1178* 5 70504B 57 310801110 714.50 718.60FUR 4 ICR1 R 1.1@-3 -20. 68 3.4@-3 0.3 2 COL SPARSELY PHYRIC BASALT,ALT MOD,PCE NUMBER= 3 C1178* 4 70504B 58 1 300 320 723.50 723.81FUR 4 ICR1 R 1.9@-3 8. 147 3.5@-3 2. 2 COL SPARSELY TO MOD PHYRIC BASALT,ALT MOD,PCE 3 CNUMBER=1192* 4 70504B 58 1 880 900 723.50 724.39FUR 4 ICR1 R 3.2@-3 11. 80 3.2@-3 3. 2 CPLAG-OL MOD PHYRIC BASALT,ALT MOD,PCE NUMBER= 3 C1200* 4 70504B 58 2 200 230 723.50 725.22FUR 4 ICR1 R 1.3@-3 7. 65 2.9@-3 1.3 2 CPLAG-OL MOD PHYRIC BASALT,ALT MOD,PCE NUMBER= 3 C1208,STA INC?* 4 70504B 58 2 680 710 723.50 725.70FUR 4 ICR1 R 0.8@-3 11. 56 3.6@-3 0.7 2 CPLAG-OL MOD PHYRIC BASALT,ALT MOD,PCE NUMBER= 3 C1214,STA INC?* 4 70504B 58 2 800 830 723.50 725.82FUR 4 ICR1 R 0.5@-3 13. 61 3.4@-3 0.4 2 CPLAG-OL MOD PHYRIC BASALT,ALT MOD,PCE NUMBER= 3 C1214,STA INC?* 4 70504B 58 3 900 930 723.50 727.42FUR 4 ICR1 R 1.6@-3 9. 69 3.2@-3 1.5 2 CPLAG-OL MOD PHYRIC BASALT,ALT SLIGHT,PCE NUMBER= 3 C1235,STA INC?* 4 70504B 60 1 480 500 741.50 741.99FUR 3 ICR1 R 1.7@-3 -21. 114 3.1@-3 1.7 2 CAPHYRIC BASALT,ALT SLIGHT,PCE NUMBER=1260* 3 70504B 60 2 410 440 741.50 743.42FUR 3 ICR1 R 13.8@-3 -20. 88 2.2@-3 19. 2 COL-PLAG PHYRIC BASALT,ALT MOD,PCE NUMBER=1275* 3 70504B 60 2 560 741.50 743.56PECH 5 ISR1 R 1000.@-6 2 X 400 1.068 121 3 CAPHYRIC TO PLAG-OL MOD PHYRIC BASALT,ALT 4 CSLIGHTLY,PCE NUMBER=1277* 5 70504B 61 1 890 920 750.50 751.41FUR 4 ICR1 R 19.9@-3 -72. 217 1.5@-3 41. 2 CPLAG-OL MOD PHYRIC BASALT,ALT MOD,PCE NUMBER= 3 C1291* 4 70504B 61 2 800 830 750.50 752.82FUR 6 ICR1 R 2 XC 245 3 XH 415 4 CPLAG-OL MOD PHYRIC BASALT,ALT MOD,PCE NUMBER= 5 C1306* 6 70504B 61 3 20 50 750.50 753.53FUR 4 ICR1 R 14.3@-3 -27. 182 1.9@-3 23. 2 CPLAG-OL MOD PHYRIC BASALT,ALT MOD,PCE NUMBER= 3 C1315* 4 70504B 62 110701090 755.00 756.08FUR 6 ICR1 R 2 XH 420 3 XC 195 4 CPLAG-OL MOD PHYRIC BASALT,ALT MOD,PCE NUMBER= 5 C1327* 6 70504B 62 11220 755.00 756.22PECH 5 ISR1 R 615.@-6 2 X 455 0.656 287 3 CPLAG-OL MOD PHYRIC BASALT,ALT EXT,PCE NUMBER= 4 C1328* 5 70504B 62 112401270 755.00 756.26FUR 4 ICR1 R 25.0@-3 -62. 275 1.6@-3 65. 2 CPLAG-OL MOD PHYRIC BASALT,ALT SLIGHT,PCE NUMBER= 3 C1329* 4 70504B 62 2 30 60 755.00 756.55FUR 4 ICR1 R 16.1@-3 -82. 130 3.1@-3 16. 2 CPLAG-OL MOD PHYRIC BASALT,ALT MOD,PCE NUMBER= 3 C1332* 4 70504B 63 2 890 920 764.00 766.41FUR 4 ICR1 R 7.0@-3 -63. 105 3.4@-3 6. 2 CPLAG-OL MOD PHYRIC BASALT,ALT MOD,PCE NUMBER= 3 C1367* 4 70504B 63 3 150 764.00 767.15PECH 5 ISR1 R 1692.@-6 2 X 445 1.098 93 3 CPLAG-OL MOD PHYRIC BASALT,ALT MOD,PCE NUMBER= 4 C1377* 5 70504B 63 4 460 490 764.00 768.98FUR 3 ICR1 R 7.0@-3 -69. 65 4.6@-3 4.6 2 CPLAG-OL PHYRIC BASALT,ALT MOD,PCE NUMBER=1395* 3 70504B 64 2 280 773.00 774.78PECH 4 ISR1 R 2153.@-6 2 X 475 1.714 86 3 CAPHYRIC BASALT,ALT SLIGHTLY,PCE NUMBER=1423* 4 70504B 64 212901320 773.00 775.81FUR 3 ICR1 R 8.5@-3 -58. 41 4.6@-3 6. 2 CAPHYRIC BASALT,ALT MOD,PCE NUMBER=1437* 3 70504B 64 4 30 773.00 777.53PECH 5 ISR1 R 2287.@-6 2 X 470 1.478 87 3 CPLAG-PYX PHYRIC BASALT,ALT SLIGHTLY,PCE NUMBER= 4 C1459* 5 70504B 64 4 30 50 773.00 777.54FUR 6 ICR1 R 2 XC 455 3 XH 455 4 CPLAG-PYX PHYRIC BASALT,ALT MOD,PCE NUMBER=1459* 5 C1327* 6 70504B 65 1 150 180 782.00 782.17FUR 4 ICR1 R 5.6@-3 -67. 77 3.3@-3 5. 2 CPLAG-OL PHYRIC TO MOD PHYRIC BASALT,ALT SLIGHT, 3 CPCE NUMBER=1475* 4 70504B 66 2 210 240 791.00 792.73FUR 4 ICR1 R 10.9@-3 -37. 82 3.9@-3 8. 2 CPLAG-OL PHYRIC TO MOD PHYRIC BASALT,ALT SLIGHT, 3 CPCE NUMBER=1509* 4 70504B 66 2 560 791.00 793.06PECH 4 ISR1 R 2734.@-6 2 X 490 1.926 93 3 CAPHYRIC BASALT,ALT SLIGHTLY,PCE NUMBER=1512* 4 70504B 66 2 580 610 791.00 793.10FUR 3 ICR1 R 1.7@-3 -37. 84 5.8@-3 0.9 2 CAPHYRIC BASALT,ALT SLIGHT,PCE NUMBER=1512* 3 70504B 69 1 720 750 818.00 818.74FUR 3 ICR1 R 3.8@-3 -32. 61 6.1@-3 1.9 2 CAPHYRIC BASALT,ALT MOD,PCE NUMBER=1545* 3 70504B 70 1 200 230 827.00 827.22FUR 6 ICR1 R 2 XC 570 3 XH 575 4 CPLAG-OL-CPX SPARSELY TO MOD PHYRIC BASALT,ALT 5 CMOD,PCE NUMBER=1550* 6 70504B 70 1 860 827.00 827.86PECH 5 ISR1 R 1325.@-6 2 X 500 1.186 146 3 CPLAG-OL-CPX MOD PHYRIC BASALT,ALT SLIGHTLY,PCE 4 CNUMBER=1557* 5 70504B 70 1 950 980 827.00 827.97FUR 4 ICR1 R 1.6@-3 -26. 100 2.4@-3 1.5 2 CPLAG-OL-CPX MOD PHYRIC BASALT,ALT SLIGHT,PCE 3 CNUMBER=1559* 4 70504B 70 113701400 827.00 828.39FUR 3 ICR1 R 0.9@-3 -35. 101 3.9@-3 0.7 2 COPHITIC BASALT,ALT SLIGHT,PCE NUMBER=1562* 3 70504B 70 2 90 120 827.00 828.60FUR 3 ICR1 R 1.6@-3 -34. 148 3.6@-3 1.3 2 COPHITIC BASALT,ALT MOD,PCE NUMBER=1564* 3 70504B 70 2 210 240 827.00 828.73FUR 5 ICR1 R 2 XH 530 3 XC 530 4 COPHITIC BASALT,ALT MOD,PCE NUMBER=1565* 5